Der Blätterkatalog benötigt Javascript.
Bitte aktivieren Sie Javascript in Ihren Browser-Einstellungen.
The Blätterkatalog requires Javascript.
Please activate Javascript in your browser settings.
50 6 1 Assignment of storage location To avoid measurement errors the measured values of the last 20 or 35 seconds are retrieved to form a value depending on the intended use Hence after each change in the inventory you should wait before the delayed display shows the change without fluctuations 1 The storage location must be empty before configuration The calibration process is initiated with “Tara” 1 2 If the measured value 2 is zero ±2 cm then the desired item is scanned with the help of the hand scan - ner Within a few seconds the product data is displayed in the field on the right 3 3 In the next step the highest possible quantity of a product is counted and stored The number is entered using the keypad 4 4 If the measured value 2 does not show any changes the quantity is confirmed using “Calibrate” 5 It is recommended to check whether the specific value 6 then displayed can be matched approximately Deviations of over 30% indicate an error in the storage location 5 The system determines the number of goods 7 based on the distance between the reflector and the ultrasound sensor 6 Clicking on “Back” 8 or “Overview” 9 will take you back to the controller overview 7 Every change is immediately applied and saved Image 3 Submenu for assignment of a storage location 1 3 6 7 8 9 4 5 2